Size and weight Dependent on configuration at aproximately 25 kg.
Length: 460 mm (w/o lamphousing), width: 333 mm, height: 480 mm (depending on tube and configuration)
Dependent on configuration at aproximately 18 kg.
Length: 410 mm (with lamphousing), width: 331 mm, height: 505 mm (depending on tube and configuration)
With A/B module = 456 mm height, 220 mm width, 396 mm depth, weight 12 kg
Nosepiece 6x (M25), centerable, encoded 5x (M25), centerable 4x (M25), centerable
Eypieces, usable field of view (FOV) 25 / 22 / 20 mm FOV 22 / 20 mm FOV 20 mm FOV
Illumination incident and transmitted High-power LED High-power LED High-power LED
  Optional:
Halogen 12V / 100W
External light source for fluorescence excitation Leica EL6000
Hg lamphouses (mercury)
Optional:
Halogen 12V / 100W
External light source for fluorescence excitation Leica EL6000
Hg lamphouses (mercury)
 
Incident light axis Motorized, 4-fold turret, illumination and contrast manager Manual, 4-fold turret, color-coded diaphragm assistant (CDA) Manual, fixed brightfield beamsplitter
Incident light Polarization contrast
Brightfield
DIC
Fluorescence
Polarization contrast
Brightfield
DIC
Fluorescence
UC-3D illumination
Polarization contrast
Brightfield
Oblique illumination
Transmitted light axis Motorized condensor operation, illumination and contrast managment Manual condenser operation with color-coded diaphragm assistant (CDA) Manual condenser operation with color-coded diaphragm assistant (CDA)
Transmitted light Polarization contrast
Orthoscopy
Conoscopy
Brightfield
Phase contrast
DIC
Darkfield
Polarization contrast
Orthoscopy
Conoscopy
Brightfield
Phase contrast
DIC
Darkfield
Polarization contrast
Orthoscopy
Conoscopy
Brightfield
Phase contrast
Darkfield
Stage 360° rotatable polarization stage with verniers and brake
360° rotatable polarization stage with verniers, 45° clickstop position, and brake
Stage carrier for adaptation of 3rd party stages
Scanning stage 100x100
Scanning stage 75x50
Manual xy stages
360° rotatable polarization stage with verniers and brake
360° rotatable polarization stage with verniers, 45° clickstop position and brake
Stage carrier for adaptation of 3rd party stages
Scanning stage 75x50
Manual xy stages
Fixed 360° rotatable polarization stage with verniers and brake
Focus drive 25-mm stage stroke of coarse and fine drive
45-50-mm total stage stroke depending on stage and condenser type
Fine drive: 0.2 mm per turn of the knob (1 scale interval = 2 mm)
Coarse drive: 3.5 mm per turn of the knob
Motorization on request
25-mm stage stroke
xx-xx mm total stage stroke depending on stage and condenser type
2-gear focus drive (coarse / fine) with 1mm scale
3-gear focus drive (coarse / medium / fine) with 1 and 4 mm scale, torque adjustment, and adjustable upper focus stop
Motorization on request
17-mm stage stroke
Conoscopy Fully integrated coded conoscopy module, additional 1.6x magnification changer, user guidance by display feedback
Advanced conoscopy module (manual)
Bertrand lens cube
Bertrand lens module (A/B module)
Advanced conoscopy module (manual)
Bertrand lens module (AB module)
A/B module with focusable Bertrand lens
Analyzer Fixed analyzer
180° rotatable analyzer
360° rotatable analyzer
Polarizer 360° polarizer for incidend light
360° polarizer for transmitted light
Fixed polarizer with lambda plate
Fixed polarizer with 0°, 45° and 90° positions
90° polarizer with rotatable lambda plate
Polarizer in holder for transmitted light
Compensatores l, l/4, quartz plate (0.-4. Order), tilting compensatores