Contact Us
Leica EM GP2 Automatic Plunge Freezer Liquefier Head

User Safety 

Safe and reproducible preparation for single particle analysis and cryo-tomography.

  • Special rapid condensing liquefier head for easy and save fill of secondary cryogen
  • Fixed secondary cryogen position, only environmental chamber movement

Sample Safety

  • Dry Nitrogen Gas Flow environment
  • Sample Storage and Transfer in liquid face using transfer container with pre-cooled grid box
  • Customized adapter for optimized and safe sample transfer from the automatic plunge freezer EM GP2 to different cryo TEMs

Fluid or Thin Sample Preparation

To prepare vitrified thin samples for cryo-TEM, including biological suspensions and industrial emulsions in both aqueous and inorganic solvents, the bare grid technique is used.

Reproducibility

Freezing grids reproducibly and safely using the EM GP2 automatic plunge freezer.

  • Sensor blotting gives equal distributes surface on grid for perfect imaging results
  • Temperature stability of secondary cryogen
  • Temperature and humidity controlled protected environment
Leica EM GP2 Automatic Plunge Freezer Detail for EM Sample Preparation, Grid Plunging
Leica EM GP2 Automatic Plunge Freezer Detail for EM Sample Preparation, Grid Plunging

Reproducible Results Within Minutes

Micrographs A and B show images of microtubules acquired at 20000x (A) and 39000x (B) nominal magnification in the holes of the perforated carbon film. The ice is free of exogenous contamination, the protofilaments and the individual tubulin subunits are clearly visible along the length of the microtubules.

Microtubules acquired at 20000x Microtubules acquired at 39000x

Courtesy of Dr. Guenter Resch, Nexperion e.U. – Solutions for Electron Microscopy; Dr. Thomas Heuser and Marlene Brandstetter, Vienna, Biocenter Core Facilities GmbH

Connectivity

To be connected at any time at any place is today something which is taken for granted.

As a logical consequence Leica Microsystems started to connect systems for EM Sample Preparation to ensure your samples are protected during the complete workflow process.

Person handling Leica EM Cryo CLEM Docking Cryo transfer shuttle
Person handling Leica EM Cryo CLEM Docking Cryo transfer shuttle

Flexibility

Depending on your needs the EM GP2 automatic plunge freezer can be configured individually by using different blotting types and parameters:

  • Sensor controlled blotting
  • Automated or manual single, double and multiple blotting
  • Environmental parameter – Temperature and Humidity
  • Blotting Parameter – Pre-Blot, Blot, Post-Blot time, Blot and Transfer Positions
Scroll to top